• Grid status — 50 Hz nominal
  • 100 kVA – 100 MVA
  • Up to 132 kV class
  • 650 kV BIL impulse tested
  • IEC 60076 · IS 2026 · IEEE C57
  • Vadodara works — FAT lab open
ENGINEERING EXCELLENCE & R&D

Precision Engineering. Dependable Performance.

Every Resonant transformer begins with rigorous electromagnetic design, computational fluid thermal modeling, and stringent dielectric insulation stress analysis to deliver three decades of zero-breakdown grid operation.

2D & 3D Finite Element Analysis

Electromagnetic Field Simulation & FEA

Advanced electromagnetic modeling maps flux distribution inside the core and magnetic leakage fields in tank walls. This minimizes stray losses, avoids local tank overheating, and optimizes conductor transposition.

Stray Loss Mitigation: Up to 22%
Thermal Profile & Oil Convection Modeling

Computational Fluid Dynamics (CFD)

Simulations calculate laminar oil velocity through winding cooling ducts and radiator fins. This eliminates thermal bottlenecks and ensures the hot-spot temperature rise complies with IEC 60076 thermal limits.

Hotspot Margin: Strictly < 65K Rise
Transient Impulse Voltage Stress Grading

Dielectric Insulation Systems

Electrostatic field mapping along pressboard barriers, angle rings, and winding leads guarantees safety margins under steep lightning impulses (1.2/50 μs) and switching surges up to 650 kV BIL.

Partial Discharge: < 10 pC at 1.3 Um
Axial & Radial Electromagnetic Force Analysis

Dynamic Short-Circuit Withstand

Under downstream dead short-circuits, forces on transformer windings can exceed hundreds of kilonewtons. We calculate hoop stress and axial tilting forces, utilizing pre-stressed hydraulic clamping rings.

Standard: IEC 60076-5 Dynamic Verification
CUSTOM ENGINEERING PORTFOLIO

Tailored for Demanding Industrial Conditions

Standard catalogue designs often fall short when deployed in harmonic-rich solar plants or high-vibration metallurgical facilities. Our engineering department designs application-specific solutions:

Multi-Winding Inverter Duty

Solar PV split LV windings with dedicated electrostatic shielding screens between primary and secondary coils to isolate high-frequency inverter harmonics.

Arc Furnace Duty (EAF/LF)

High-current secondary busbars handling up to 55,000 Amperes with internal water-cooled copper tubes and extreme cyclic mechanical bracing.

Dual-Voltage & Uprated Units

Transformers configured with external switchgear or internal series-parallel links allowing utilities to migrate from 11 kV to 33 kV without transformer replacement.

Consult our electrical engineering team with your site parametersSubmit Electrical Parameters