• Grid status — 50 Hz nominal
  • 100 kVA – 100 MVA
  • Up to 132 kV class
  • 650 kV BIL impulse tested
  • IEC 60076 · IS 2026 · IEEE C57
  • Vadodara works — FAT lab open
Resonant 50 MVA 132 kV substation power transformer
Resonant / Transformers

ReliablepowerforEveryIndustry.

Substation and industrial transformers with verified loss guarantees, extreme dielectric integrity, and 30+ years of continuous grid operation.

Voltage class
0kV
Max capacity
0MVA
BIL impulse tested
0kV
Partial discharge
<0pC
  • Power Transformers
  • Distribution
  • Dry-Type Cast Resin
  • Oil-Immersed
  • Arc Furnace Duty
  • Renewable Inverter Duty
  • Engineered in Vadodara
  • Tested to 650 kV BIL
  • IEC 60076
  • IS 2026
  • IEEE C57
  • Partial discharge < 10 pC

[ 02 ] Catalogue — 05 product families

Solutions for every application.

Engineered solutions for modern power networks, demanding industries, and critical infrastructure.

View full range
50 MVA 132 kV Power Transformer
Primary power class01 / 04

50 MVA 132 kV Power Transformer

Engineered for transmission substations and utility grids — 16-step on-load tap changer, low-noise radiator cooling banks, and full Buchholz protection.

Cooling
ONAN / ONAF
Ratio
132 / 33 kV
Vector
Dyn11 / YNd11
Standard
IEC 60076 · IS 2026
View details
2500 kVA Dry-Type
Cast resin02 / 04

2500 kVA Dry-Type

Epoxy cast resin coils engineered for zero fire risk in commercial high-rises, hospitals, and high-density data centers.

View details
1000 kVA Distribution
Distribution03 / 04

1000 kVA Distribution

Corrugated fin tank technology delivering maximum heat dissipation in a compact footprint with a low no-load silicon steel core.

View details
30 MVA Arc Furnace
Special duty — 55,000 A04 / 04

30 MVA Arc Furnace

High-current water-cooled copper busbars engineered for repeated short-circuits and severe cyclic metallurgical shocks.

View details

[ Interactive engineering visualization ] Select a component

Inside the machine.

Core geometry, continuously transposed copper windings, and vacuum-sealed fluid containment — part by part.

3D cutaway illustration of an industrial power transformer showing core and windings

Fig. — Cutaway, hover a marker

  • Continuously Transposed Conductors (CTC) wound in disc and helical configurations with thermally upgraded kraft paper and high-density pressboard spacers.

    Material
    99.99% ETP / OFHC Copper (CTC)
    Standard
    IEC 60076-5 (Short-Circuit Tested)
    Performance
    101% IACS Conductivity
    Rating
    Class A (105°C) / Class F (155°C)

    Performance guaranteeHigh radial and axial clamping rigidity withstands severe electromagnetic forces during external through-fault short circuits.

[ 03 ] Engineering → Manufacturing → Testing

From simulation to impulse.

Explore capabilities
01 / DesignFEA
Electromagnetic Core Simulation

Electromagnetic Core Simulation

Step-lap mitered core stacking using laser-scribed prime CRGO silicon steel to minimize hysteresis losses and excitation currents.

02 / DesignCFD
Computational Fluid Dynamics

Computational Fluid Dynamics

Thermal modeling of transformer oil velocity and radiator convection to eliminate localized winding hotspots.

03 / BuildInsulation
Dielectric Insulation & Impulse Grading

Dielectric Insulation & Impulse Grading

High-density pre-compressed pressboard barriers guaranteeing partial discharge levels strictly below 10 picocoulombs.

04 / Verify100% routine
Voltage Ratio & Vector Group

Voltage Ratio & Vector Group

Verified phase displacement, polarity, and transformation ratio on every unit before it leaves Vadodara.

05 / VerifyType test
Lightning Impulse Withstand

Lightning Impulse Withstand

Full wave 1.2/50 μs impulse surge applied from a multi-stage Marx generator up to 650 kV, with digital oscillograms.

06 / VerifyDielectric
Partial Discharge & Tan Delta

Partial Discharge & Tan Delta

Discharge levels verified strictly below 10 picocoulombs. Insulation power factor logged for the lifetime record.

[ 05 ] The Resonant standard

Reliability
is engineered.

01

Application-Specific Design

Custom engineered tap ranges, impedance matching, and thermal profiles built specifically for site duty cycles.

02

Verified Prime Materials

Laser-scribed prime CRGO silicon steel, 99.9% oxygen-free copper, and certified dielectric fluids.

03

Rigorous Quality Gates

Multi-stage quality hold points: core loss checks, coil surge tests, tank vacuum testing, and impulse FAT.

04

Lifecycle Technical Support

Field service engineers providing installation supervision, commissioning, oil testing, and emergency spares.

[ 06 ] Technical consultation

Let's engineer your next power solution.

Discuss your transformer requirements with our engineering team and explore the right solution for your application.

  1. 01Feasibility review within 24 business hours
  2. 02Budgetary quotation with guaranteed loss figures
  3. 03Direct consultation with transformer designers

Tel — +91 (265) 288-0000

Mail — sales@resonantequipment.com

Quotation

Form RT-01